7 lb. ft. MagneClutch (7MC*90C)
SEE TABS BELOW FOR SPECS & RESOURCES
3D MODEL AVAILABLE UPON REQUEST
Available Cooling Types.
- Model 7MC90C convection cooled.
- Model 7MCA90C forced air cooled.
Multiple Options.
- 90 Volt. Available in other voltages to order.
- Choice of torque ratings.
- Water or forced air cooled.
Small Size & Weight.
- Size tailored to application.
- Simpler handling & mounting.
Efficient Configuration.
- C-Face mounting unit.
- Received ready to use.
- Direct coupling to drive or load.
Flexibility.
- Use as brake or clutch in reeling applications.
- Wind-unwind tension control.
- Adapts to production fixtures.
- Soft acceleration control for delicate materials.
3D MODEL AVAILABLE UPON REQUEST
Available Cooling Types.
- Model 7MC90C convection cooled.
- Model 7MCA90C forced air cooled.
Multiple Options.
- 90 Volt. Available in other voltages to order.
- Choice of torque ratings.
- Water or forced air cooled.
Small Size & Weight.
- Size tailored to application.
- Simpler handling & mounting.
Efficient Configuration.
- C-Face mounting unit.
- Received ready to use.
- Direct coupling to drive or load.
Flexibility.
- Use as brake or clutch in reeling applications.
- Wind-unwind tension control.
- Adapts to production fixtures.
- Soft acceleration control for delicate materials.
Model 7MC90C / 7MCA90C
Data sheet
- Model
- 7MC90C / 7MCA90C
- Rated Torque (lb.-ft.)
- 7
- Mounting
- C-Face (1)
- Type Of Cooling
- Convection (CV) / Forced Air (FA)
- Heat Dissipation at 1800 RPM (Watts) (5)
- 300 (CV) / 940 (FA)
- Max Oper. Speed (RPM) (6)
- 3600
- Non-Excited Drag Torque (lb.-ft.)
- 0.25
- Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - OUTER
- 2.0
- Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - INNER
- 3.3
- Wgt. Approx (lbs.)
- 21 (CV) / 29 (FA)
- Coil Data (Input 90VDC) - CURRENT AMPERES (4)
- 0.26
- Coil Data (Input 90VDC) - RESISTANCE OHMS @ 20 C
- 257
- Note (1)
- Utilize NEMA 56C Motor
- Note (4)
- Coils for other voltages wound to order
- Note (5)
- The data given represents the average, continuous dissipation capacity of units operating under slip conditions
- Note (6)
- Applications requiring continuous operation below 30 RPM should be referred to factory for evaluation