25 lb. ft. MagneBrake (25MB*90C)
SEE TABS BELOW FOR SPECS & RESOURCES
Available Cooling Types.
- Model 25MB90C convection cooled.
- Model 25MBA90C forced air cooled.
- Standard 90VDC coil. Available in other voltages to order.
Wide Industry Use.
- Printing, Machine tools, Plastic film, Wire & more.
- Increasing use in all tension control areas.
Proven Performance.
- NEMA-C Face.
- Countless applications.
- Success in tough industrial environments.
Convenience.
- Simple shaft mounting.
- Unique flange for oversized shaft.
- Compact, easy to install,
- Easily serviceable.
Fast Response.
- Rapid stopping.
- Precise Control.
- Combines with Magneclutch for stop-go cycling.
Economical.
- Near-unlimited braking life.
- Inexpensive life-extension kit.
Available Cooling Types.
- Model 25MB90C convection cooled.
- Model 25MBA90C forced air cooled.
- Standard 90VDC coil. Available in other voltages to order.
Wide Industry Use.
- Printing, Machine tools, Plastic film, Wire & more.
- Increasing use in all tension control areas.
Proven Performance.
- NEMA-C Face.
- Countless applications.
- Success in tough industrial environments.
Convenience.
- Simple shaft mounting.
- Unique flange for oversized shaft.
- Compact, easy to install,
- Easily serviceable.
Fast Response.
- Rapid stopping.
- Precise Control.
- Combines with Magneclutch for stop-go cycling.
Economical.
- Near-unlimited braking life.
- Inexpensive life-extension kit.
Model 25MB90C / 25MBA90C
Data sheet
- Model
- 25MB90C / 25MBA90C
- Rated Torque (lb.-ft.)
- 25
- Mounting
- C-Face (1)
- Type Of Cooling
- Convection
- Heat Dissipation at 1800 RPM (Watts) (5)
- 300 (CA) / 750 (FA)
- Max Oper. Speed (RPM) (6)
- 3600
- Non-Excited Drag Torque (lb.-ft.)
- 0.50
- Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - OUTER
- -
- Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - INNER
- 4.5
- Wgt. Approx (lbs.)
- 21 (CV) / 29 (FA)
- Coil Data (Input 90VDC) - CURRENT AMPERES (4)
- 0.26
- Coil Data (Input 90VDC) - RESISTANCE OHMS @ 20 C
- 257
- Note (1)
- Utilize NEMA 56C Motor
- Note (2)
- Coils for other voltage wound to order
- Note (3)
- Data given represents the average, continuous dissipation capacity of units operating under slip conditions
- Note (4)
- Applications requiring operation below 30 RPM should be referred to factory for evaluation